              For this study, a knife -edge margin was selected. Avail-  3. Ruse ND, Sadoun MJ. Resin -composite Blocks for Dental CAD/
           able literature relates this preparation design to crowns with   CAM Applications. J Dent Res. 2014;93:1232 -4.
           lower resistance values but still higher than the occlusal   4. Goujat A, Abouelleil H, Colon P, Jeannin C. Mechanical
                        34
           loads described. Although the type of margin was not one   properties and internal fit of 4 CAD -CAM block materials. J
                                                                 Prosthet Dent. 2018;119:384 -9.
           of the variables studied in this study, it is also expected to   5. Rosentritt M, Hahnel S, Engelhardt F, Behr M. In vitro
           affect the evaluated material. Therefore, studies focused on   performance and fracture resistance of CAD/CAM -fabricated
           the relationship between margin design and fracture resis-  implant supported molar crowns. Clin Oral Invest.
           tance are needed. Moreover, future studies should replicate   2017;21:1213 -9.
           the conditions of the oral environment by applying cyclic   6. Ferracane JL. Resin composite–state of the art. Dent Mater.
           and/or thermodynamic loads to mimic the fatigue suffered   2011;27:29 -38.
           by restorations.                                     7. Gracis S, Thompson VP, Ferencz JL, Silva NR, Bonfante EA.
                                                                 A new classification system for all -ceramic and ceramic-
                                                                 -like restorative materials. Int J Prosthodont. 2015;28:227-
                                                                 -35.
           Conclusions                                          8. Mainjot AK, Dupont NM, Oudkerk JC, Dewael TY, Sadoun MJ.
                                                                 From Artisanal to CAD -CAM Blocks: State of the Art of
           Crowns  cemented  with  self -adhesive  resin  cement  showed   Indirect Composites. J Dent Res. 2016;95:487 -95.
           higher fracture resistance than those cemented with RMGI,   9. Awada A, Nathanson D. Mechanical properties of resin-
           making it preferable to the cementation of full -contour resin   -ceramic CAD/CAM restorative materials. J Prosthet Dent.
                                                                 2015;114:587 -93.
           nanoceramic crowns.                                 10. Coldea A, Swain MV, Thiel N. Mechanical properties of
                                                                 polymer -infiltrated ceramic -network materials. Dent Mater.
                                                                 2013;29:419 -26.
           Acknowledgments                                     11. Charlton DG, Roberts HW, Tiba A. Measurement of select
                                                                 physical and mechanical properties of 3 machinable ceramic
                                                                 materials. Quintessence Int. 2008;39:573 -9.
           The authors would like to thank GC Corporation for providing   12. Mormann WH, Bindl A, Luthy H, Rathke A. Effects of
           the CAD/CAM blocks and cements evaluated in this study.
                                                                 preparation and luting system on all -ceramic computer-
                                                                 -generated crowns. Int J Prosthodont. 1998;11:333-9.
                                                               13. Bindl A, Luthy H, Mormann WH. Strength and fracture
           Ethical disclosures                                   pattern of monolithic CAD/CAM -generated posterior crowns.
                                                                 Dent Mater. 2006;22:29-36.
           Protection of human and animal subjects. The  authors   14. Lim M, Lee K. Effect of adhesive luting on the fracture
           declare that no experiments were performed on humans or   resistance of zirconia compared to that of composite resin
                                                                 and lithium disilicate glass ceramic. Restor Dent Endod.
           animals for this study.
                                                                 2017;42:1-8.
                                                               15. Attia A, Abdelaziz KM, Freitag S, Kern M. Fracture load of
           Confidentiality of data. The authors declare that no patient
           data appear in this article.                          composite resin and feldspathic all -ceramic CAD/CAM
                                                                 crowns. J Prosthet Dent. 2006;95:117-23.
           Right to privacy and informed consent. The authors declare   16. Weyhrauch M, Igiel C, Scheller H, Weibrich G, Lehmann KM.
           that no patient data appear in this article.          Fracture Strenght of Monolithic All -Ceramic Crowns on
                                                                 Titanium Implant Abutments. Int J Oral Maxillofac Implants.
                                                                 2016;31:304 -9.
                                                               17. Castro EF, Azevedo VLB, Nima G, Andrade OS, Dias CTDS,
           Conflict of interest                                  Giannini M. Adhesion, Mechanical Properties, and
                                                                 Microstructure of Resin -matrix CAD -CAM Ceramics. J Adhes
           The authors have no conflicts of interest to declare.  Dent. 2020;22:421 -31.
                                                               18. Yoshihara K, Nagaoka N, Maruo Y, Nishigawa G, Irie M,
                                                                 Yoshida Y, Van Meerbeek B. Sandblasting may damage the
                                                                 surface of composite CAD -CAM blocks. Dent Mater.
           orcid                                                 2017;33:e124 -35. Epub 2017 Jan 2.
                                                               19. Jorgensen K. Acta Odontol Scand. Factors affecting the film
           Joana Guerreiro      0000-0001-7614-4666              thickness of zinc phosphate cements. 2009;18:479 -90.
                                                               20. Sorrentino R, Nagasawa Y, Infelise A, Bonadeo G, Ferrari M. In
           Rafael Dias      0000-0003-2334-9945
                                                                 Vitro Analysis of the Fracture Resistance of Cad -Cam
           José Carracho      0000-0002-4583-1866                Cerasmart Molar Crowns with Different Occlusal Thickness.
                                                                 Biomed J Sci Tech Res. 2018;3:3074-9.
                                                               21. Ferrario VF, Sforza C, Serrao G, Dellavia C, Tartaglia GM. Single
                                                                 tooth bite forces in healthy young adults. J Oral Rehabil.
           references                                            2004;31:18-22.
                                                               22. Okada R, Asakura M, Ando A, Kumano H, Ban S, Kawai T, et al.
            1. Al -Musawi RMA, Farid F. Computer -Based Technologies in   Fracture strength testing of crowns made of CAD/CAM
              Dentistry: Types and Applications. J Dent (Tehran).   composite resins. J Prosthodont Res. 2018;62:287-92.
              2016;13:215 -22.
            2. Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an   23. Nakamura K, Mouhat M, Magnus J, Jenssen S, Kanno T,
                                                                 Milleding P, et al. Effect of cements on fracture resistance of
              overview of recent developments for CAD/CAM generated   monolithic zirconia crowns. Acta Biomater Odontol Scand.
              restorations. Br Dent J. 2008;204:505 -11.
                                                                 2016;2:12 -9.
   24   25   26   27   28   29   30   31   32   33   34