Page 40 - SPEMD_58-2
P. 40
96 rev port estomatol med dent cir maxilofac. 2017;58(2):91-96
measurement: a cross-sectional clinical study. Med Oral Patol 16. Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison
Oral Cir Bucal. 2013;18:e877-82. between cutting torque and resonance frecuency
8. Jaramillo R, Santos R, Lázaro P, et al. Comparative analysis of measurements of maxillary implants. A 20 month clinical
2 resonance frequency measurement devices: Osstell Mentor study. Int J Oral Maxillofac Surg. 1999;28:297-303.
and Osstell ISQ. Implant Dent. 2014;23:351-6. 17. Abrahamsson I, Berglundh T, Lindhe J. The mucosal barrier
9. Sennerby L, Meredith N. Implant stability measurements using following abutment dis/reconnection. An experimental study
resonance frequency analysis: biological and biomechanical in dogs. J Clin Periodontol. 1997;24:568-72.
aspects and clinical implications Periodontol 2000. 2008;47:51-66. 18. Lazzara RJ, Porter SS. Platform switching: a new concept in
10. Pagliani L1, Sennerby L, Petersson A, Verrocchi D, Volpe S, implant dentistry for controlling postrestorative crestal
Andersson P. l. The relationship between resonance bone levels. Int J Periodontics Restorative Dent. 2006;
frequency analysis (RFA) and lateral displacement of dental 26:9-17.
implants: an in vitro study. J Oral Rehabil. 2013;40:221-7. 19. Lekholm U, Zarb G. Patient selection and preparation. In:
11. Sennerby L, Roos J. Surgical determinants of clinical success Branemark P, Zarb G, Albrektsson T, ed. Tissue-Integrated
of osseointegrated oral implants A review of the literature. Prostheses. Osseointegration in Dentistry, 1st ed. Chicago,
Int J Prosthodont. 1998;11:408-20. Quintessence Publishing Co., Inc. 1985:199-209.
12. Friberg B, Sennerby L, Linden B, Gröndahl K, Lekholm U. 20. Andrés-García R, Vives NG, Climent FH, et al. In vitro
Stability measurements of one-stage Brånemark implants evaluation of the infuence of the cortical bone on the
during healing in mandibles. A clinical resonance frequency primary stability of two implant systems. Med Oral Patol Oral
analysis study. Int J Oral Maxillofac Surg. 1999;28:266-72. Cir Bucal. 2009;14:E93-7.
13. Sim CP, Lang NP. Factors infuencing resonance frequency 21. Romanos GE, Ciornei G, Jucan A, et al. In vitro assessment of
®
analysis assessed by Osstell mentor during implant tissue primary stability of Straumann implant designs. Clin
integration: I. Instrument positioning, bone structure, Implant Dent Relat Res. 2014;16:89-95.
implant length. Clin Oral Implants Res. 2010;21:598-604. 22. Misch CE. Implant design considerations for the posterior
14. Meredith N, Shagaldi F, Alleyne D, Sennerby L, Cawley P.The regions of the mouth. Implant Dent. 1999;8:376-86.
application of resonance frequency measurements to study 23. Meredith N. Assessment of implant stability as a prognostic
the stability of titanium implants during healing in the rabbit determinant. Int J Prosthodont. 1998;11:491-501.
tibia. Clin Oral Implants Res. 1997;8:234-43. 24. Ostman Po, hellman M, Sennerby L. Direct implant loading
15. Bischof M1, Nedir R, Szmukler-Moncler S, Bernard JP, Samson in the edentulous maxilla using a bone density-adapted
J. Implant stability measurement of delayed and immediately surgical protocol and primary implant stability criteria
loaded implants during healing. Clin Oral Implants Res. for inclusion. Clin Implant Dent Relat Res. 2005;
2004;15:529-39. 7(Suppl 1):S60-9.

